British Journal of Anaesthesia, 2002, Vol. 89, No. 4 546-550
© 2002 The Board of Management and Trustees of the British Journal of Anaesthesia
Clinical Investigations |
Xenon has no effect on cytokine balance and adhesion molecule expression within an isolated cardiopulmonary bypass system
1 Anaesthesia and Intensive Care Medicine, The Royal Group of Hospitals Trust, Grosvenor Road, Belfast BT12 6BA, 2 Department of Anaesthetics and Intensive Care Medicine and 3 Department of Microbiology and Immunobiology, Queens University of Belfast, Whitla Medical Building, 97 Lisburn Road, Belfast BT9 7BL, UK*Corresponding author: Department of Anaesthetics and Intensive Care Medicine, Whitla Medical Building, 97 Lisburn Road, Belfast BT9 7BL, UK
Declaration of interest. We are grateful to Polystan UK who provided the cardiopulmonary bypass circuits for this study. This study was supported by a grant from BOC gases (UK) for the ELISA assays and supply of xenon. Dr Bedi was supported by a Research Fellowship from the Association of Anaesthetists of Great Britain and Ireland (19982000).
This work was presented as an abstract to the Anaesthetic Research Society.
Background. Although almost inert chemically, xenon is not unreactive biologically. It interacts with receptors involved in the expression of cytokines and adhesion molecules. The effect of xenon on the immune function in whole blood has not been studied.
Methods. We examined the effects of 70% xenon in oxygen on cytokine balance and expression of adhesion molecules in an isolated cardiopulmonary bypass (CPB) system, which simulates an evolving inflammatory response. Whole blood from 10 healthy male volunteers was circulated in a CBP system supplied with either 70% xenon in oxygen, or oxygen-enriched air FO2=0.3 (control). We took samples of blood after 30, 60 and 90 min of simulated CBP. We measured interleukin (IL)-1ß, tumour necrosis factor (TNF)
, IL-8, IL-10, IL-1ra and TNF-sr-2 levels, and the expression of HLA-DR and the adhesion molecules L-selectin, CD18 and CD11b on monocytes, granulocytes and lymphocytes.
Results. IL-8 concentrations were increased significantly, TNF-sr-2 concentrations decreased significantly and IL-10 levels decreased during bypass. There were no significant differences between the groups for any measured variable.
Conclusion. In an isolated CPB system, xenon and oxygen-enriched air had similar effects on cytokine production and expression of adhesion molecules.
Br J Anaesth 2002; 88: 54650
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
S. Allen, W. T McBride, I. S Young, S. W MacGowan, T. J McMurray, S. Prabhu, S P. Penugonda, and M. A Armstrong A clinical, renal and immunological assessment of Surface Modifying Additive Treated (SMARTTM) cardiopulmonary bypass circuits Perfusion, September 1, 2005; 20(5): 255 - 262. [Abstract] [PDF] |
||||
![]() |
R. D. Sanders, D. Ma, and M. Maze Xenon: elemental anaesthesia in clinical practice Br. Med. Bull., February 22, 2005; 71(1): 115 - 135. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. T. McBride, N. Khalil, P. Elliott, and M. Armstrong Clomethiazole Alters Immune Function Within an Isolated Cardiopulmonary Bypass Circuit Anesth. Analg., April 1, 2004; 98(4): 1191 - 1191. [Full Text] [PDF] |
||||