Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (67)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by OLSSON, S. G.
Right arrow Articles by PRAKASH, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by OLSSON, S. G.
Right arrow Articles by PRAKASH, O.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 1980, Vol. 52, No. 5 491-499
© 1980 The Board of Management and Trustees of the British Journal of Anaesthesia


research-article

CLINICAL STUDIES OF GAS EXCHANGE DURING VENTILATORY SUPPORT–A METHOD USING THE SIEMENS-ELEMA CO2 ANALYZER

S. G. OLSSON, R. FLETCHER, F.F.A.R.C.S., B. JONSON, M.D., L. NORDSTRÖM, M.D. and O. PRAKASH, M.D.

Siemens-Elema Company, Solna, Sweden
Department of Anaesthesia, University Hospital Lund, Sweden
Department of Clinical Physiology University Hospital Lund, Sweden
Thoraxcenter, Eiramus University Rotterdam, The Netherlands

We describe a new portable infra-red analyser for use with the Siemens-Elema Servo ventilator. The sensor head constitutes a Y-piece connecting the patient to the ventilator tubing, and gives instant carbon dioxide determination. It is based upon simple principles that can be realized with modern techniques, offering for instance freedom from interference by anaesthetic gases, and eliminating the need for calibration. A non-zero inspired carbon dioxide concentration interferes with the measurements. Integration of the carbon dioxide signal with the flow signal from the Servo ventilator yields data about carbon dioxide excretion, and additional calculation yields VD/VT if Paco1 is known. The accuracy of determination of end-tidal carbon dioxide and carbon dioxide elimination was found to be adequate for research purposes, and that of VD/VT for clinical purposes. The device is considered to be of value in the operating theatre and intensive care unit, for monitoring, as a guide to ventilatory needs, and for the investigation of the magnitude and causes of increased deadspace.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
M. B. Jaffe
Infrared Measurement of Carbon Dioxide in the Human Breath: "Breathe-Through" Devices from Tyndall to the Present Day
Anesth. Analg., September 1, 2008; 107(3): 890 - 904.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
Y. Tang, M. J. Turner, and A. B. Baker
Systematic errors and susceptibility to noise of four methods for calculating anatomical dead space from the CO2 expirogram
Br. J. Anaesth., June 1, 2007; 98(6): 828 - 834.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
S. M Romano, S. Scolletta, I. Olivotto, B. Biagioli, G. F. Gensini, M. Chiostri, and P. Giomarelli
Systemic arterial waveform analysis and assessment of blood flow during extracorporeal circulation
Perfusion, March 1, 2006; 21(2): 109 - 116.
[Abstract] [PDF]


Home page
Anesth. Analg.Home page
R. P. R. Smith and R. Fletcher
Positive End-Expiratory Pressure Has Little Effect on Carbon Dioxide Elimination After Cardiac Surgery
Anesth. Analg., January 1, 2000; 90(1): 85 - 85.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.